Test equipment Basic – Semiautomatic and Manual Test Equipment

The Basic test equipments from the highlab and basic series are characterized by their flexibility and modularity. The outstanding technical data of the integrated microprocessor and interface technology, which measure the values, can be processed elegantly in this tester equipment segment through the erfi test software CANDY Power which displays the high level of performance characteristics of this product series.

Testing for:
- High voltage
- Insulation
- Ground wire
- Leakage current

Due to the modular structure, the components become complete VDE0113 / EN60204 testers. This device series is particularly suitable for customers who check small to medium quantities and thus a manual contacting of the device using HV guns, protective conductor test bars, etc. is sufficient for testing.

Key data high voltage

Size: 19 "/ 3HE
Type of test: manual / semi-automatic
Test voltage: 0-5 kV AC (manual)
Alternative: 0-7 kV DC
Output power: 500 VA
Short circuit current:> 200mA
Analog display: for U and I
Shutdown current: infinitely adjustable from 2 to 120 mA Burnout function
Test duration: 1 to 99 sec.
Start: front and back
Number of copies: optical and acoustic
Contact: punch or error message
Analogue interface: optional with CANDY testing software

Key data isolation

Size: 3U / 28 TE
Type of test: manual / semi-automatic
Test voltage: 500 V DC
Alternative: 500/1000 V DC, switchable
Digital display: for insulation resistance value
Threshold: Rmin and Rmax
Test duration: 1 to 99 sec.
Start: front and back
Error indication: optically by digital display and acoustically
Back contact: error message
RS232 interface: standard, to query the resistance measured values
Analogue interface: optional with CANDY testing software

Key data protective conductor

Size: 3U / 56 TE
Type of test: manual / semi-automatic
Test current: 10/25 A AC switchable
Digital display: for protective conductor resistance value
Threshold: Rmin and Rmax
Test duration: 1 to 99 sec.
Start: front and back
Error indication: optically by digital display and acoustically
Back contact: error message
RS232 interface: standard, to query the resistance measured values
Analogue interface: optional with CANDY testing software

Key data Leakage current

Size: 3U / 56 TE
Test type: manual
Test: 1-phase version up to 10 A
Digital display: for leakage current value
Type of test: Type A and Type B, switchable
Infeed: by external transformer
Measuring ranges: 500 μA / 5 mA switchable
Interfaces: without interface

We will gladly advise you!