Register now for the 4th erfi Innovation Day! +++ Contact us +49 (0) 7441 9144 404 +++ more

Test Combination 3: High Voltage, Insulation, Protective Conductor and Leakage Current Testing

Test Combination 3 offers three different high-voltage output stages:
Category 1: Current-limited
Category 2: 500 VA power and 100% duty cycle

On request, test voltages up to 7,500 V AC and 7,000 V DC can be realized. All models are already standardly designed for 5 kV AC and 7 kV DC tests. An insulation test is also included as standard with all models. All models switch fully automatically between the individual output stages. The test object does not need to be reconnected!

Category 1 – Current Limited

General

  • Size: 19″ / 9U (rack units)
  • Test type: manual / semi-automatic / fully automatic
  • Display: menu navigation with test assistant
  • Memory: up to 80 test programs
  • Start: rear side
  • RS232 interface: remote control of all device functions

 

High voltage testing

  • Test voltage: 0-5 kV AC, 0-7 kV DC, electronically generated
  • Output power: 15 VA
  • Ramp function: 100 to 7000 V/s, separate rise and fall ramp
  • Short-circuit current: < 3 mA
  • Test duration: 1 to 99 seconds
  • Breakdown indicator: visual and acoustic
  • Current measurement: apparent and active current measurement
  • Limit values: Imin, Imax

 

Insulation test

  • Test voltage: 0–1 kV DC, electronically controlled (also up to 7 kV DC)
  • Test duration: 1 to 99 seconds
  • Limit values: Rmin, Rmax
  • Measuring range: at least up to 1 GΩ

 

Protective conductor test

  • Test current: 5 to 30 A AC, electronically regulated
  • Method: resistance, voltage drop according to VDE 0113, conductor cross-section
  • Test duration: 1 to 99 seconds
  • Limit values: Rmin, Rmax
  • Measuring range: up to 300 mΩ

 

Leakage current test

  • Quality: also suitable for medical devices (EN 60601)
  • Standards: standard configuration includes 4 standards (of your choice)
  • Standard equipment:
    • VDE 0700 (EN 60335) Household appliances,
    • E 0711 (EN 60598) Luminaires,
    • VDE 0805 (EN 60950) Office equipment,
    • VDE 0750 (EN 60601) Medical devices.
  • Test objects: Single-phase up to 10 A, three-phase unlimited (with additional switching matrix).
  • Measurements: Earth leakage current, enclosure leakage current, patient leakage current, and more.
  • Method: Fully automatic switching between measurements L1-N/PE, etc.
  • Limit values: Imin, Imax
  • Power supply: external input
  • Additional standards: EN 60990 (rated and unrated currents), and more.

Category 2 – 500 VA power and 100% duty cycle

General

  • Size: 19″ / 12U (12 height units)
  • Test type: manual / semi-automatic / fully automatic
  • Display: menu navigation with test assistant
  • Memory: up to 80 test programs
  • Start: rear side
  • RS232 interface: complete remote control of all device functions
  • Duty cycle: 100% duty cycle (100% ED)

 

High voltage testing

  • Test voltage: 0-5 kV AC, 0-7 kV DC, electronically generated
  • Output power: 500 VA
  • Ramp function: 100 to 7000 V/s, separate rise and fall ramp
  • Short-circuit current: at least 200 mA
  • Test duration: 1 to 999 seconds
  • Breakdown indication: visual and acoustic
  • Current measurement: apparent and active current measurement
  • Limit values: Imin, Imax, Itrip
  • Burn-in function

 

Insulation test

  • Test voltage: 0–1 kV DC, electronically controlled (also up to 7 kV DC)
  • Test duration: 1 to 999 seconds
  • Limit values: Rmin, Rmax
  • Measuring range: at least up to 1 GΩ

 

Protective conductor test

  • Test current: 5 to 30 A AC, electronically regulated
  • Method: resistance, voltage drop according to VDE 0113, conductor cross-section
  • Test duration: 1 to 999 seconds
  • Limits: Rmin, Rmax
  • Measuring range: up to 300 mΩ

 

Leakage current test

  • Quality: also suitable for medical devices (EN 60601)
  • Standards: standard configuration includes 4 standards (of your choice)
  • Standard equipment:
    • VDE 0700 (EN 60335) Household appliances,
    • VDE 0711 (EN 60598) Luminaires,
    • VDE 0805 (EN 60950) Office equipment,
    • VDE 0750 (EN 60601) Medical devices

 

  • Test objects: Single-phase up to 10 A, three-phase unlimited (with additional switching matrix).
  • Measurements: Earth leakage current, enclosure leakage current, patient leakage current, and more.
  • Method: Fully automatic switching between measurements L1-N/PE, etc.
  • Limit values: Imin, Imax
  • Power supply: external input
  • Additional standards: EN 60990 (evaluated and non-evaluated currents) and others.
How the collaboration works

erfi – Your partner for innovative and reliable work and learning environments

1. Consulting and Planning

Together with you, we develop tailor-made solutions for your laboratory and workplace requirements. Our experts provide comprehensive consulting to understand your individual needs and present innovative ideas. Rely on our many years of experience and expertise to create the ideal foundation for your projects.

2. Development and Production

In our state-of-the-art manufacturing facility, we efficiently bring your ideas to life. Utilizing advanced technology and a skilled team, we ensure the highest quality and flexibility. Our in-house development allows us to respond quickly to your requirements and deliver tailor-made solutions.

3. Implementation and Support

After production, we support you during the implementation of our systems. Our experts work closely with you to ensure seamless integration into your processes. With ongoing support and targeted training, we help you unlock the full potential of your new solutions – ensuring efficient and reliable operation from day one.

Request catalog

Get advice now

    Successful!
    Thank you for your inquiry. We will attend to your request promptly.
    Your erfi team in Freudenstadt

    I agree that my data will be collected and stored electronically in accordance with the privacy policy.

    Products

    Discover more products from erfi

    Areas of application

    Our modular systems combine ergonomics, functionality and the highest quality – for use in electrical laboratories, assembly environments, technical training and demanding test procedures.

    Workstation systems

    Workstation systems are essential for an efficient work environment in laboratories, industry, and office spaces. At erfi, we offer well-designed solutions that combine flexibility, ergonomics, and technological innovation.

    Measuring and test equipment

    The “elneos six” capacitive device series stands for DC and AC laboratory power supplies, digital multimeters, power meters, function and arbitrary generators.

    Test and analysis systems

    Our test and inspection systems for safety and functionality, combined with the CANDY software, enable integrated product development across all industries.

    Didactic systems

    The learning fields at erfi range from Industry 4.0 automation to tasks in building technology. The surface is robust, abrasion-resistant, and sealed.

    Software

    The control programs from erfi – CANDY Power, highlink Power and AWM – offer optimum control and overview.
    This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.